Cluster Queue Date of arrival Nodes CPU Cores Memory Storage Network
sol default 2007-02-23 49 2 x AMD Opteron 2218 2 cores/CPU 4 GB 232 GB HDD [1-28]: 1 Gbps 
[29-35,37-50]: 1 Gbps + 10 Gbps Myrinet
suno default 2010-01-27 45 2 x Intel Xeon E5520 4 cores/CPU 32 GB [1-27,29-45]: 557 GB HDD
[28]: 278 GB HDD
1 Gbps 
uva default 2016-07-01 13 4 x Intel Xeon E7450 6 cores/CPU 64 GB 136 GB HDD 1 Gbps + 2 x 40 Gbps InfiniBand
uvb default 2016-07-01 44 2 x Intel Xeon X5670 6 cores/CPU 96 GB 232 GB HDD 1 Gbps + 2 x 40 Gbps InfiniBand

Cluster details

sol

49 nodes, 98 cpus, 196 cores, split as follows due to differences between nodes (json)

sol-[1-2,4-5,8-9,11-19,21-24,26-28] (22 nodes, 44 cpus, 88 cores)
Model: Sun Fire X2200 M2
Date of arrival: 2007-02-23
CPU: AMD Opteron 2218 K8 (2 CPUs/node, 2 cores/CPU)
Memory: 4 GB
Storage: 232 GB HDD SATA HITACHI HDS7225S (driver: sata_nv)
Network:
  • eth0/enp0s8, Ethernet (driver: forcedeth), configured rate: 1 Gbps
  • eth1/enp0s9, Ethernet (driver: forcedeth), configured rate: n/c - unavailable for experiment

sol-[3,6-7,10,20] (5 nodes, 10 cpus, 20 cores)
Model: Sun Fire X2200 M2
Date of arrival: 2007-02-23
CPU: AMD Opteron 2218 K8 (2 CPUs/node, 2 cores/CPU)
Memory: 4 GB
Storage: 232 GB HDD SATA HITACHI HDS7225S (driver: sata_nv)
Network:
  • eth0, Ethernet (driver: forcedeth), configured rate: 1 Gbps
  • eth1, Ethernet (driver: forcedeth), configured rate: n/c - unavailable for experiment

sol-[25] (1 node, 2 cpus, 4 cores)
Model: Sun Fire X2200 M2
Date of arrival: 2007-02-23
CPU: AMD Opteron 2218 K8 (2 CPUs/node, 2 cores/CPU)
Memory: 4 GB
Storage: 232 GB HDD SATA SEAGATE ST32500N (driver: sata_nv)
Network:
  • eth0/enp0s8, Ethernet (driver: forcedeth), configured rate: 1 Gbps
  • eth1/enp0s9, Ethernet (driver: forcedeth), configured rate: n/c - unavailable for experiment

sol-[29-30,32-33,35,37-39,41,43-46,48,50] (15 nodes, 30 cpus, 60 cores)
Model: Sun Fire X2200 M2
Date of arrival: 2007-02-23
CPU: AMD Opteron 2218 K8 (2 CPUs/node, 2 cores/CPU)
Memory: 4 GB
Storage: 232 GB HDD SATA HITACHI HDS7225S (driver: sata_nv)
Network:
  • eth0/enp0s8, Ethernet (driver: forcedeth), configured rate: 1 Gbps
  • eth1/enp0s9, Ethernet (driver: forcedeth), configured rate: n/c - unavailable for experiment
  • myri0, Myrinet (driver: mx ethernet (myri)), configured rate: 10 Gbps

sol-[31,40,42,47,49] (5 nodes, 10 cpus, 20 cores)
Model: Sun Fire X2200 M2
Date of arrival: 2007-02-23
CPU: AMD Opteron 2218 K8 (2 CPUs/node, 2 cores/CPU)
Memory: 4 GB
Storage: 232 GB HDD SATA HITACHI HDS7225S (driver: sata_nv)
Network:
  • eth0, Ethernet (driver: forcedeth), configured rate: 1 Gbps
  • eth1, Ethernet (driver: forcedeth), configured rate: n/c - unavailable for experiment
  • myri0, Myrinet (driver: mx ethernet (myri)), configured rate: 10 Gbps

sol-[34] (1 node, 2 cpus, 4 cores)
Model: Sun Fire X2200 M2
Date of arrival: 2007-02-23
CPU: AMD Opteron 2218 K8 (2 CPUs/node, 2 cores/CPU)
Memory: 4 GB
Storage: 232 GB HDD SATA SEAGATE ST32500N (driver: sata_nv)
Network:
  • eth0/enp0s8, Ethernet (driver: forcedeth), configured rate: 1 Gbps
  • eth1/enp0s9, Ethernet (driver: forcedeth), configured rate: n/c - unavailable for experiment
  • myri0, Myrinet (driver: mx ethernet (myri)), configured rate: 10 Gbps

suno

45 nodes, 90 cpus, 360 cores, split as follows due to differences between nodes (json)

suno-[1-2,8-9,11,14-15,20,22-25,27,30-37,42-44] (24 nodes, 48 cpus, 192 cores)
Model: Dell PowerEdge R410
Date of arrival: 2010-01-27
CPU: Intel Xeon E5520 Nehalem 2.27GHz (2 CPUs/node, 4 cores/CPU)
Memory: 32 GB
Storage: 557 GB HDD SAS PERC 6/i Adapter (driver: megaraid_sas)
Network:
  • eth0/eno1, Ethernet (driver: bnx2), configured rate: 1 Gbps
  • eth1/eno2, Ethernet (driver: bnx2), configured rate: n/c - unavailable for experiment

suno-[3,5-6,10,16-17,21,38-41,45] (12 nodes, 24 cpus, 96 cores)
Model: Dell PowerEdge R410
Date of arrival: 2010-01-27
CPU: Intel Xeon E5520 Nehalem 2.27GHz (2 CPUs/node, 4 cores/CPU)
Memory: 32 GB
Storage: 557 GB HDD SAS PERC 6/i Adapter (driver: megaraid_sas)
Network:
  • eth0, Ethernet (driver: bnx2), configured rate: 1 Gbps
  • eth1, Ethernet (driver: bnx2), configured rate: n/c - unavailable for experiment

suno-[4,7,12-13,18-19,26,29] (8 nodes, 16 cpus, 64 cores)
Model: Dell PowerEdge R410
Date of arrival: 2010-01-27
CPU: Intel Xeon E5520 Nehalem 2.27GHz (2 CPUs/node, 4 cores/CPU)
Memory: 32 GB
Storage: 557 GB HDD SAS PERC 6/i Adapter (driver: megaraid_sas)
Network:
  • eth0/enp1s0f0, Ethernet (driver: bnx2), configured rate: 1 Gbps
  • eth1/enp1s0f1, Ethernet (driver: bnx2), configured rate: n/c - unavailable for experiment

suno-[28] (1 node, 2 cpus, 8 cores)
Model: Dell PowerEdge R410
Date of arrival: 2010-01-27
CPU: Intel Xeon E5520 Nehalem 2.27GHz (2 CPUs/node, 4 cores/CPU)
Memory: 32 GB
Storage: 278 GB HDD SAS PERC 6/i Adapter (driver: megaraid_sas)
Network:
  • eth0/eno1, Ethernet (driver: bnx2), configured rate: 1 Gbps
  • eth1/eno2, Ethernet (driver: bnx2), configured rate: n/c - unavailable for experiment

uva

13 nodes, 52 cpus, 312 cores, split as follows due to differences between nodes (json)

uva-[1,4,9-10,12-13] (6 nodes, 24 cpus, 144 cores)
Model: Dell PowerEdge R900
Date of arrival: 2016-07-01
CPU: Intel Xeon E7450 Dunnington 2.40GHz (4 CPUs/node, 6 cores/CPU)
Memory: 64 GB
Storage: 136 GB HDD SAS PERC 6/i (driver: megaraid_sas)
Network:
  • eth0/enp5s0, Ethernet (driver: bnx2), configured rate: 1 Gbps
  • eth1/enp7s0, Ethernet (driver: bnx2), configured rate: n/c - unavailable for experiment
  • eth2/enp9s0, Ethernet (driver: bnx2), configured rate: n/c - unavailable for experiment
  • eth3/enp11s0, Ethernet (driver: bnx2), configured rate: n/c - unavailable for experiment
  • ib0, InfiniBand (driver: mlx4_core), configured rate: 40 Gbps
  • ib0.8100, InfiniBand (driver: mlx4_core), configured rate: 40 Gbps

uva-[5] (1 node, 4 cpus, 24 cores)
Model: Dell PowerEdge R900
Date of arrival: 2016-07-01
CPU: Intel Xeon E7450 Dunnington 2.40GHz (4 CPUs/node, 6 cores/CPU)
Memory: 64 GB
Storage: 136 GB HDD SAS PERC 6/i (driver: megaraid_sas)
Network:
  • eth0, Ethernet (driver: bnx2), configured rate: 1 Gbps
  • eth1, Ethernet (driver: bnx2), configured rate: n/c - unavailable for experiment
  • eth2, Ethernet (driver: bnx2), configured rate: n/c - unavailable for experiment
  • eth3, Ethernet (driver: bnx2), configured rate: n/c - unavailable for experiment
  • ib0, InfiniBand (driver: mlx4_core), configured rate: 40 Gbps
  • ib0.8100, InfiniBand (driver: mlx4_core), configured rate: 40 Gbps

uva-[2-3,6-8,11] (6 nodes, 24 cpus, 144 cores)
Model: Dell PowerEdge R900
Date of arrival: 2016-07-01
CPU: Intel Xeon E7450 Dunnington 2.40GHz (4 CPUs/node, 6 cores/CPU)
Memory: 64 GB
Storage: 136 GB HDD SAS PERC 6/i (driver: megaraid_sas)
Network:
  • eth0/eno1, Ethernet (driver: bnx2), configured rate: 1 Gbps
  • eth1/eno2, Ethernet (driver: bnx2), configured rate: n/c - unavailable for experiment
  • eth2/eno3, Ethernet (driver: bnx2), configured rate: n/c - unavailable for experiment
  • eth3/eno4, Ethernet (driver: bnx2), configured rate: n/c - unavailable for experiment
  • ib0, InfiniBand (driver: mlx4_core), configured rate: 40 Gbps
  • ib0.8100, InfiniBand (driver: mlx4_core), configured rate: 40 Gbps

uvb

44 nodes, 88 cpus, 528 cores, split as follows due to differences between nodes (json)

uvb-[1-2,4-6,8-29,31,33-44] (40 nodes, 80 cpus, 480 cores)
Model: Dell PowerEdge C6100
Date of arrival: 2016-07-01
CPU: Intel Xeon X5670 Westmere 2.93GHz (2 CPUs/node, 6 cores/CPU)
Memory: 96 GB
Storage: 232 GB HDD SATA WDC WD2502ABYS-1 (driver: ahci)
Network:
  • eth0/eno1, Ethernet (driver: igb), configured rate: 1 Gbps
  • eth1/eno2, Ethernet (driver: igb), configured rate: n/c - unavailable for experiment
  • ib0, InfiniBand (driver: mlx4_core), configured rate: 40 Gbps
  • ib0.8100, InfiniBand (driver: mlx4_core), configured rate: 40 Gbps
  • ib1, InfiniBand (driver: mlx4_core), configured rate: n/c - unavailable for experiment

uvb-[3,7,30,32] (4 nodes, 8 cpus, 48 cores)
Model: Dell PowerEdge C6100
Date of arrival: 2016-07-01
CPU: Intel Xeon X5670 Westmere 2.93GHz (2 CPUs/node, 6 cores/CPU)
Memory: 96 GB
Storage: 232 GB HDD SATA WDC WD2502ABYS-1 (driver: ahci)
Network:
  • eth0, Ethernet (driver: igb), configured rate: 1 Gbps
  • eth1, Ethernet (driver: igb), configured rate: n/c - unavailable for experiment
  • ib0, InfiniBand (driver: mlx4_core), configured rate: 40 Gbps
  • ib0.8100, InfiniBand (driver: mlx4_core), configured rate: 40 Gbps

Generated from the Grid5000 APIs on 2018-04-18